{"title":"Wiggins - Valves","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","products":[{"product_id":"wiggins-jn-receiver-jnx-01-64-25","title":"Wiggins JNX-01-64-25 Fast Fueling Systems | Standard Automatic Shutoff Valve (Replaced P\/N JNXRF)","description":"\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eJNX-01-64-25 Wiggins Standard Automatic Shutoff Valve - JNX\/JVX Non-Pressurized Fueling System Utilizing ZZ9A1 \u0026amp; ZZ9A2 Nozzles\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eJN Receiver, W\/JIC Fitting and Flange \u003c\/span\u003e(Previously JNXRF)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFEATURES:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2\" JIC adapter for fuel transfer hose\u003c\/li\u003e\n\u003cli\u003eBolt on mounting flange to mate with weld-on VR310-11 flange on base of fuel cell\u003c\/li\u003e\n\u003cli\u003eDesigned to work with the \u003ca href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-jvx\" title=\"JVX Wiggins Vent with Jet Sensor\"\u003eJVX\u003c\/a\u003e (short) or the \u003ca href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-jvxl-long-jv-jet-level-sensor-vent\" title=\"JVXL Wiggins Long JV Jet Level Sensor\/Vent for Non-Pressurized Fueling Systems\"\u003eJVXL\u003c\/a\u003e (Long) Jet Level sensor\/vent\u003c\/li\u003e\n\u003cli\u003eMaximum flow rate 211 gpm (800 lpm)\u003c\/li\u003e\n\u003cli\u003eMinimum Flow rate 25 gpm (95 lpm)\u003c\/li\u003e\n\u003cli\u003eOperating pressure of 75 PSIG (520 kPa)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch6\u003e\u003cspan style=\"color: #38761d;\"\u003eRead below to learn more about Wiggins Patented JNX Fast Fueling Systems\u003c\/span\u003e\u003c\/h6\u003e\n\u003ch5\u003e\n\u003cbr\u003e\u003cstrong\u003eThe Patented JNX Series Non-Pressurizing Fast Fueling System\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(Fast, Clean and ULTRA SAFE)\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003eThe Wiggins JNX non pressurizing system allows for automatic diesel refueling at up to 211 gpm (800 lpm) with existing Wiggins nozzles and does not pressurize the fuel tank.  Shutoff is automatic, fully self contained and cannot be overridden.  \u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eCompetitors' Non Pressurizing Systems\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eCompetitors' non pressurizing systems use float valves and are FAIL OPEN systems.  They will overfill and pressurize the fuel tank if fueling is carried out with a faulty float valve or bleed hose.  (Competitors' systems commonly make use of an internal bleed hose, which is vulnerable to fatigue due to fuel slosh.)  In this situation, fuel continues to bleed through the faulty float valve or hose even when the fuel level has passed the required shutoff point, preventing pressure from equalizing across the shutoff piston.  The pressure imbalance keeps the piston open and fuel continues to flow into the tank unchecked.  Consequently, the tank overfills and is pressurized in proportion to the flow rate - the higher the flow rate, the greater the spillage and pressure build up - creating a potentially severe safety and environmental hazard. \u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eThe Wiggins Patented ULTRA SAFE JNX System\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eThe Wiggins JNX system represents a technological leap forward in non pressurizing automatic diesel refueling systems.  The JNX system uses conventional pressure sensitive fuel nozzles such as the Wiggins ZZ9A1 and ZZ9A2 while providing users with unique fail shut and overfill resistant features not matched by the competition. \u003c\/p\u003e\n\u003cp\u003eThe Wiggins JNX shutoff valve is FAIL SHUT: the spring closed main valve can only be opened by a pressure signal from the jet level sensor - if for any reason the pressure signal is lost, the main valve will close, shutting off the flow of fuel into the tank.  This ensures that overfilling the tank is not possible even if any part of the jet level sensor or signal hose were to fail.\u003c\/p\u003e\n\u003cp\u003eThe unique Wiggins jet level sensor does not have any moving parts to wear out and is thus extremely reliable.  The Wiggins non pressurizing system uses only external signal hoses, making JNX easy to install and maintain.  The JNX system is available in both direct and remote fill configurations. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003cimg alt=\"PDF File Downloads of Product Data Sheets \u0026amp; SDS Sheets\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/PDF_file_download_icon.png?v=1538683502\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e PDF DOWNLOADS: \u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cimg alt=\"Industrial Lubricant Company\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/Download-Attachments-Industrial-Lubricant-Company_8b86c1ec-b95e-4a20-b4a4-9de8fc282d20.png?v=1501098692\" data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/Wiggins-JNX-01-64-25-Fast-Fueling-Systems-Standard-Automatic-Shutoff-Valve.pdf?v=1602858123\" title=\"Wiggins JNX-01-64-25 Fast Fueling Systems Standard Automatic Shutoff Valve\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eWiggins JNX-01-64-25 Fast Fueling Systems | Standard Automatic Shutoff Valve (Replaced P\/N JNXRF)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/warning_image-transparent_icon.png?v=1547219676\" alt=\"\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWARNING: \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eSome metal products may contain elements or chemicals known to the State of California to cause cancer, birth defects, or reproductive harm.  These elements include but are not limited to Chromium, Cobalt, Lead, and Nickel. For more information visit \u003c\/span\u003e\u003ca href=\"http:\/\/www.P65Warnings.ca.gov\" data-mce-fragment=\"1\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e\u003c\/p\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e","brand":"Wiggins","offers":[{"title":"Default Title","offer_id":29909819276,"sku":"JNX-01-64-25","price":4393.28,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/300_-_Wiggins-JN-Receiver-JNX-01-64-25.jpg?v=1753299267"},{"product_id":"wiggins-jnx-01-64","title":"Wiggins JNX-01-64 Fast Fueling Systems | JN Standard Shutoff Receiver Valve with Fitting (Replaced P\/N JNXR)","description":"\u003ch4\u003eJNX-01-64 Wiggins Standard Automatic Shutoff Valve with Fitting - JNX\/JVX Non-Pressurized Fueling System Utilizing ZZ9A1 \u0026amp; ZZ9A2 Nozzles\u003c\/h4\u003e\n\u003cp\u003eJN receiver, with JIC fitting, previously JNXR\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFEATURES:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounts to lower portion of fuel tank via a \u003ca title=\"Wiggins CSPF-C007 Half Coupling with 2 Inch NPT Weld - Fast Fuel Tank Vents\" href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-cspf-c007-half-coupling-with-2-npt-weld\"\u003eCSPF-C007\u003c\/a\u003e half coupling\u003c\/li\u003e\n\u003cli\u003eDesigned to work with the\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Wiggins JVX Vent With Jet Sensor - JNX\/JVX Non-Pressurized Fueling System Utilizing ZZ9A1 \u0026amp; ZZ9A2 Nozzles\" href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-jvx\"\u003eJVX\u003cspan\u003e \u003c\/span\u003e\u003c\/a\u003e(short) or the\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Wiggins JVXL Long JV Jet Level Sensor\/Vent - JNX\/JVX Non-Pressurized Fueling System Utilizing ZZ9A1 \u0026amp; ZZ9A2 Nozzles\" href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-jvxl-long-jv-jet-level-sensor-vent\"\u003eJVXL\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003e(long) jet level sensor\/vent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTECHNICAL SPECS:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2\" JIC adapter for fuel transfer hose connection\u003c\/li\u003e\n\u003cli\u003e2\" NPT male thread for mounting to fuel tank\u003c\/li\u003e\n\u003cli\u003eMaximum flow rate 211 gpm (800 lpm)\u003c\/li\u003e\n\u003cli\u003eMinimum flow rate 25 gpm (95 lpm)\u003c\/li\u003e\n\u003cli\u003eOperating pressure of 75 psig (520 kPa)\u003c\/li\u003e\n\u003cli\u003eWeight - 3.74 lbs. (1.79 kg) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch6\u003e\u003cspan style=\"color: #38761d;\"\u003eRead below to learn more about Wiggins Patented JNX Fast Fueling Systems\u003c\/span\u003e\u003c\/h6\u003e\n\u003ch5\u003e\n\u003cbr\u003e\u003cstrong\u003eThe Patented JNX Series Non-Pressurizing Fast Fueling System\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(Fast, Clean and ULTRA SAFE)\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003eThe Wiggins JNX non pressurizing system allows for automatic diesel refueling at up to 211 gpm (800 lpm) with existing Wiggins nozzles and does not pressurize the fuel tank.  Shutoff is automatic, fully self contained and cannot be overridden.  \u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eCompetitors' Non Pressurizing Systems\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eCompetitors' non pressurizing systems use float valves and are FAIL OPEN systems.  They will overfill and pressurize the fuel tank if fueling is carried out with a faulty float valve or bleed hose.  (Competitors' systems commonly make use of an internal bleed hose, which is vulnerable to fatigue due to fuel slosh.)  In this situation, fuel continues to bleed through the faulty float valve or hose even when the fuel level has passed the required shutoff point, preventing pressure from equalizing across the shutoff piston.  The pressure imbalance keeps the piston open and fuel continues to flow into the tank unchecked.  Consequently, the tank overfills and is pressurized in proportion to the flow rate - the higher the flow rate, the greater the spillage and pressure build up - creating a potentially severe safety and environmental hazard. \u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eThe Wiggins Patented ULTRA SAFE JNX System\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eThe Wiggins JNX system represents a technological leap forward in non pressurizing automatic diesel refueling systems.  The JNX system uses conventional pressure sensitive fuel nozzles such as the Wiggins ZZ9A1 and ZZ9A2 while providing users with unique fail shut and overfill resistant features not matched by the competition. \u003c\/p\u003e\n\u003cp\u003eThe Wiggins JNX shutoff valve is FAIL SHUT: the spring closed main valve can only be opened by a pressure signal from the jet level sensor - if for any reason the pressure signal is lost, the main valve will close, shutting off the flow of fuel into the tank.  This ensures that overfilling the tank is not possible even if any part of the jet level sensor or signal hose were to fail.\u003c\/p\u003e\n\u003cp\u003eThe unique Wiggins jet level sensor does not have any moving parts to wear out and is thus extremely reliable.  The Wiggins non pressurizing system uses only external signal hoses, making JNX easy to install and maintain.  The JNX system is available in both direct and remote fill configurations. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/PDF_file_download_icon.png?v=1538683502\" alt=\"PDF File Downloads of Product Data Sheets \u0026amp; SDS Sheets\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e PDF DOWNLOADS: \u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/Download-Attachments-Industrial-Lubricant-Company_8b86c1ec-b95e-4a20-b4a4-9de8fc282d20.png?v=1501098692\" alt=\"Industrial Lubricant Company\"\u003e\u003ca rel=\"noopener noreferrer\" title=\"Wiggins JNX-01-64 Fast Fueling Systems JN Standard Shutoff Receiver Valve with Fitting\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/Wiggins-JNX-01-64-Fast-Fualing-Systems-JN-Standard-Shutoff-Receiver-Valve-with-Fitting.pdf?v=1602857815\" target=\"_blank\"\u003eWiggins JNX-01-64 Fast Fueling Systems | JN Standard Shutoff Receiver Valve with Fitting (Replaced P\/N JNXR)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg data-mce-fragment=\"1\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/warning_image-transparent_icon.png?v=1547219676\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWARNING: \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eSome metal products may contain elements or chemicals known to the State of California to cause cancer, birth defects, or reproductive harm.  These elements include but are not limited to Chromium, Cobalt, Lead, and Nickel. For more information visit \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" href=\"http:\/\/www.P65Warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e\u003c\/p\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e","brand":"Wiggins","offers":[{"title":"Default Title","offer_id":33175526796,"sku":"JNX-01-64","price":4159.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/300_-_Wiggins-JNX-01-64-Parts-Fast-Fuel-Fueling-Systems-JN-Receiver-Fitting-Replaced-JNXR-Non.jpg?v=1752244876"},{"product_id":"wiggins-jnx-01-02-25-standard-jn-receiver-with-flange-replaced-p-n-jnxf","title":"Wiggins JNX-01-02-25 Fast Fueling Systems | Standard Automatic Shutoff Valve (Replaced P\/N JNXF)","description":"\u003ch4\u003eJNX-01-02-25 Wiggins Standard Automatic Shutoff Valve (Replaced P\/N JNXF) -  JNX\/JVX Non-Pressurized Fueling System Utilizing ZZ9A1 \u0026amp; ZZ9A2 Nozzles\u003ca title=\"Industrial Lubricant Company Main Website\" href=\"http:\/\/www.industriallubricant.com\/\" target=\"_blank\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFEATURES:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBolt on mounting flange to mate with weld-on VR310-11 flange on base of fuel cell\u003c\/li\u003e\n\u003cli\u003eDesigned to work with the \u003ca title=\"Wiggins JVX Vent With Jet Sensor - JNX\/JVX Non-Pressurized Fueling System Utilizing ZZ9A1 \u0026amp; ZZ9A2 Nozzles\" href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-jvx\"\u003eJVX \u003c\/a\u003e(short) or the \u003ca title=\"Wiggins JVXL Long JV Jet Level Sensor\/Vent - JNX\/JVX Non-Pressurized Fueling System Utilizing ZZ9A1 \u0026amp; ZZ9A2 Nozzles\" href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-jvxl-long-jv-jet-level-sensor-vent\"\u003eJVXL\u003c\/a\u003e (long) jet level sensor\/vent\u003c\/li\u003e\n\u003cli\u003e\n\u003ca title=\"Wiggins ZN Series products\" href=\"https:\/\/store.industriallubricant.com\/search?type=product\u0026amp;q=zn\"\u003eZN2\u003c\/a\u003e series style receiver to mate with the \u003ca title=\"Wiggins ZZ9A1 Fast Fueling Systems | Refueling Nozzle with Automatic Shut-Off - Fast Fuel Nozzles\" href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-zz9a1-fast-fuel-refueling-nozzle\"\u003eZZ9A1\u003c\/a\u003e and \u003ca title=\"Wiggins ZZ9A2 Fast Fueling Systems | Hi-Flow Diesel Refueling Nozzle with Automatic Shut-Off - Fast Fuel Nozzles\" href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-zz9a2-fast-fueling-systems-refueling-nozzle\"\u003eZZ9A2\u003c\/a\u003e fueling nozzles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTECHNICAL SPECS:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum flow rate 211 gpm (800 lpm)\u003c\/li\u003e\n\u003cli\u003eMinimum flow rate 25 gpm (95 lpm)\u003c\/li\u003e\n\u003cli\u003eOperating pressure of 75 psig (520 kPa)\u003c\/li\u003e\n\u003cli\u003eWeight - 3.94 lbs. (1.79 kg) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch6\u003e\u003cspan style=\"color: #38761d;\"\u003eRead below to learn more about Wiggins Patented JNX Fast Fueling Systems\u003c\/span\u003e\u003c\/h6\u003e\n\u003ch5\u003e\n\u003cbr\u003e\u003cstrong\u003eThe Patented JNX Series Non-Pressurizing Fast Fueling System\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(Fast, Clean and ULTRA SAFE)\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003eThe Wiggins JNX non pressurizing system allows for automatic diesel refueling at up to 211 gpm (800 lpm) with existing Wiggins nozzles and does not pressurize the fuel tank.  Shutoff is automatic, fully self contained and cannot be overridden.  \u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eCompetitors' Non Pressurizing Systems\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eCompetitors' non pressurizing systems use float valves and are FAIL OPEN systems.  They will overfill and pressurize the fuel tank if fueling is carried out with a faulty float valve or bleed hose.  (Competitors' systems commonly make use of an internal bleed hose, which is vulnerable to fatigue due to fuel slosh.)  In this situation, fuel continues to bleed through the faulty float valve or hose even when the fuel level has passed the required shutoff point, preventing pressure from equalizing across the shutoff piston.  The pressure imbalance keeps the piston open and fuel continues to flow into the tank unchecked.  Consequently, the tank overfills and is pressurized in proportion to the flow rate - the higher the flow rate, the greater the spillage and pressure build up - creating a potentially severe safety and environmental hazard. \u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eThe Wiggins Patented ULTRA SAFE JNX System\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eThe Wiggins JNX system represents a technological leap forward in non pressurizing automatic diesel refueling systems.  The JNX system uses conventional pressure sensitive fuel nozzles such as the Wiggins ZZ9A1 and ZZ9A2 while providing users with unique fail shut and overfill resistant features not matched by the competition. \u003c\/p\u003e\n\u003cp\u003eThe Wiggins JNX shutoff valve is FAIL SHUT: the spring closed main valve can only be opened by a pressure signal from the jet level sensor - if for any reason the pressure signal is lost, the main valve will close, shutting off the flow of fuel into the tank.  This ensures that overfilling the tank is not possible even if any part of the jet level sensor or signal hose were to fail.\u003c\/p\u003e\n\u003cp\u003eThe unique Wiggins jet level sensor does not have any moving parts to wear out and is thus extremely reliable.  The Wiggins non pressurizing system uses only external signal hoses, making JNX easy to install and maintain.  The JNX system is available in both direct and remote fill configurations. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/PDF_file_download_icon.png?v=1538683502\" alt=\"PDF File Downloads of Product Data Sheets \u0026amp; SDS Sheets\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e PDF DOWNLOADS: \u003c\/span\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003cimg data-mce-fragment=\"1\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/Download-Attachments-Industrial-Lubricant-Company_8b86c1ec-b95e-4a20-b4a4-9de8fc282d20.png?v=1501098692\" alt=\"Industrial Lubricant Company\"\u003e\u003ca rel=\"noopener noreferrer\" title=\"Wiggins JNX-01-02-25 Fast Fueling Systems Standard JN Receiver with Flange\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/Wiggins-JNX-01-02-25-Fast-Fueling-Systems-Standard-JN-Receiver-with-Flange.pdf?v=1602694024\" target=\"_blank\"\u003eWiggins JNX-01-02-25 Fast Fueling Systems | Standard JN Receiver with Flange (Replaced P\/N JNXF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003cp\u003e\u003cimg data-mce-fragment=\"1\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/warning_image-transparent_icon.png?v=1547219676\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWARNING: \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eSome metal products may contain elements or chemicals known to the State of California to cause cancer, birth defects, or reproductive harm.  These elements include but are not limited to Chromium, Cobalt, Lead, and Nickel. For more information visit \u003c\/span\u003e\u003ca data-mce-fragment=\"1\" href=\"http:\/\/www.P65Warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e\u003c\/p\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e","brand":"Wiggins","offers":[{"title":"Default Title","offer_id":42759471052,"sku":"JNX-01-02-25","price":4279.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/300_-_Wiggins-JNX-01-02-25-Parts-Fast-Fuel-Fueling-Systems-Standard-JN-Receiver-Flange-Replace.jpg?v=1752244876"},{"product_id":"copy-of-wiggins-defvent-diesel-exhaust-fluid-filling-systems-relief-vent-valve-for-exhaust","title":"Wiggins DEFVALVEHR Diesel Exhaust Fluid Filling Systems | Automatic Shutoff Valve","description":"\u003ch4\u003e\n\u003cspan style=\"color: #00ff00;\"\u003e(NEW)\u003c\/span\u003e DEFVALVEHR Wiggins Fast Fueling Systems | Automatic Shutoff Valve - DEF Fill Systems\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFEATURES:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCan be mounted horizontally or vertically\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFlow rate: 38 lpm (10 gpm) to 114 lpm (30gpm)\u003c\/li\u003e\n\u003cli\u003eHeater: 60W at 24 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDesign Challenges:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTanks, hoses and fittings must be prevented from freezing\u003c\/li\u003e\n\u003cli\u003eReceiver and Automatic Shutoff Valve have internal heaters\u003c\/li\u003e\n\u003cli\u003eTransfer hose between Receiver and Automatic Shutoff Valve must be heated or drained \u003c\/li\u003e\n\u003cli\u003eSystem must be designed to minimize exposure to air\u003c\/li\u003e\n\u003cli\u003eVent has check valves to minimize exposure of tank to outside air\u003c\/li\u003e\n\u003cli\u003eReceiver and nozzle have self-sealing valves that close upon disconnection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCOMPONENTS OF SYSTEM:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReceiver - \u003ca href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-defr-diesel-exhaust-fluid-filling-systems-receiver?_pos=1\u0026amp;_sid=8bc4165e6\u0026amp;_ss=r\" title=\"DEF Diesel Exhaust Fluid Fast Fueling System Receiver - DEFR\"\u003eDEFR\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eautomatic Shutoff Valve - \u003ca href=\"https:\/\/store.industriallubricant.com\/products\/copy-of-wiggins-defvent-diesel-exhaust-fluid-filling-systems-relief-vent-valve-for-exhaust?_pos=2\u0026amp;_sid=9ac14c967\u0026amp;_ss=r\u0026amp;variant=32150800138326\" title=\"DEF Diesel Exhaust Fluid Fasting Filling Systems Valve - DEFVALVE\"\u003eDEFVALVEHR\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eVent - \u003ca href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-defvent-diesel-exhaust-fluid-filling-systems-vent-valve-assembly?_pos=1\u0026amp;_sid=3c851c016\u0026amp;_ss=r\u0026amp;variant=12187947597938\" title=\"DEF Diesel Exhaust Fluid Fast Filling System Vent - DEFVENT\"\u003eDEFVENT\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eNozzle - \u003ca href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-defn-diesel-exhaust-fluid-filling-systems-refueling-nozzle-assembly?_pos=1\u0026amp;_sid=2c1dd2d9e\u0026amp;_ss=r\u0026amp;variant=12155356414066\" title=\"DEF Diesel Exhaust Fluid Fast Filling System Nozzle - DEFN\"\u003eDEFN\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/warning_image-transparent_icon.png?v=1547219676\" alt=\"\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/warning_image-transparent_icon.png?v=1547219676\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eWARNING: \u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003eSome metal products may contain elements or chemicals known to the State of California to cause cancer, birth defects, or reproductive harm.  These elements include but are not limited to Chromium, Cobalt, Lead, and Nickel. For more information visit \u003c\/span\u003e\u003ca href=\"http:\/\/www.P65Warnings.ca.gov\" data-mce-fragment=\"1\" data-mce-href=\"http:\/\/www.P65Warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e\u003c\/p\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e","brand":"Wiggins","offers":[{"title":"Default Title","offer_id":32150800138326,"sku":"DEFVALVEHR","price":8373.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/Wiggins-DEFVALVE-Adel-DEF-Diesel-Exhaust-Fluid-Fast-Fueling-System-Stainless-Steel-Corrosive-Fluids-Vent-Valve-1_e1f8f6b1-6a06-4185-a8a6-03f894109113.jpg?v=1765918637"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/collections\/462645887209.jpg?v=1775673712","url":"https:\/\/store.industriallubricant.com\/collections\/wiggins-valves-options.oembed","provider":"Industrial Lubricant","version":"1.0","type":"link"}