{"product_id":"wiggins-defvalvehr-diesel-exhaust-fluid-filling-systems-automatic-shutoff-valve-copy","title":"Wiggins JNXPH Automatic Shutoff Valve for Compact, Non-Pressurized - Fast Fuel Fill System","description":"\u003ch4\u003e\n\u003cspan style=\"color: #00ff00;\"\u003e(NEW)\u003c\/span\u003e JNXPH Wiggins Fast Fueling Systems | Automatic Shutoff Valve \u003cspan style=\"font-size: 0.875rem;\"\u003efor Compact, Non-Pressurized, Refueling System\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003cp\u003eHow the JNXPH Compact System Works \u0026gt; Automatic Shutoff Valve details\u0026gt;\u003c\/p\u003e\n\u003cp\u003eFuel flows through the Jet Level Sensor (JV23PH), creating a pressure signal to open the JNXPH valve, allowing fuel into the tank.  When the pressure signal is cut-off by the rising fuel level via the Jet Level Sensor (JV23PH), the JNXPH valve closes, stopping the fueling process.\u003c\/p\u003e\n\u003cp\u003eFEATURES:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNon-Pressurized: uses the patented and ultra-reliable Wiggins Jet Sensor Technology to control shutoff \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNew internal routing for maximum protection of signal hoses\u003c\/li\u003e\n\u003cli\u003eDoesn't pressurize tank and does not rely on floats\u003c\/li\u003e\n\u003cli\u003e2\" male NPT connection to tank\u003c\/li\u003e\n\u003cli\u003eFlow rate: 150+ gallons per minute (570+lpm)\u003c\/li\u003e\n\u003cli\u003eCompatible with Industry Standard Nozzles: ZZ9A1 and ZZ9A2\u003c\/li\u003e\n\u003cli\u003eFits flush inside ZNC3 and ZNC4 flush mount cans\u003c\/li\u003e\n\u003cli\u003eIncluded with JNXPH \u0026gt; Y-Strainer - JNX-27\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCOMPONENTS OF SYSTEM:\u003ca href=\"https:\/\/store.industriallubricant.com\/products\/copy-of-wiggins-defvent-diesel-exhaust-fluid-filling-systems-relief-vent-valve-for-exhaust?_pos=2\u0026amp;_sid=9ac14c967\u0026amp;_ss=r\u0026amp;variant=32150800138326\" title=\"DEF Diesel Exhaust Fluid Fasting Filling Systems Valve - DEFVALVE\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated Jet Level Sensor\/Vent (3 micron filtration) - JV23PH\u003c\/li\u003e\n\u003cli\u003eIntegrated Jet Level Sensor\/Vent (10 micron filtration) - JVXPH\u003c\/li\u003e\n\u003cli\u003eY-Strainer - JNX-27\u003c\/li\u003e\n\u003cli\u003eNozzle - \u003ca href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-zz9a1-fast-fuel-refueling-nozzle?_pos=1\u0026amp;_sid=72a1cf2be\u0026amp;_ss=r\" title='Wiggins ZZ9A1 Fast Fueling Systems Nozzle 1.5\"'\u003eZZ9A1\u003c\/a\u003e or \u003ca href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-zz9a2-fast-fueling-systems-refueling-nozzle?_pos=13\u0026amp;_sid=7004b388e\u0026amp;_ss=r\u0026amp;variant=12712443576406\" title='Wiggins ZZ9A2 Fast Fueling Systems Nozzle 2\"'\u003eZZ9A2\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eFlush Mount Cans - \u003ca title=\"Wiggins ZNC3 Flush Mount Can for Refueling Systems\" href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-znc3-bolted-receiver-assembly-with-half-coupling?_pos=3\u0026amp;_sid=ef3a04ec7\u0026amp;_ss=r\u0026amp;variant=42692288460\"\u003eZNC3\u003c\/a\u003e or \u003ca title=\"Wiggins ZNC4 Flush Mount Can for Refueling Systems\" href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-znc4-receiver-half-coupling-assembly-with-cap-welded?_pos=3\u0026amp;_sid=3e26b025d\u0026amp;_ss=r\u0026amp;variant=41681256908\"\u003eZNC4\u003c\/a\u003e\u003ca href=\"https:\/\/store.industriallubricant.com\/products\/wiggins-znc4-receiver-half-coupling-assembly-with-cap-welded?_pos=3\u0026amp;_sid=3e26b025d\u0026amp;_ss=r\u0026amp;variant=41681256908\"\u003e\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/warning_image-transparent_icon.png?v=1547219676\" alt=\"\"\u003e\u003cspan\u003eWARNING: \u003c\/span\u003e\u003cspan\u003eSome metal products may contain elements or chemicals known to the State of California to cause cancer, birth defects, or reproductive harm.  These elements include but are not limited to Chromium, Cobalt, Lead, and Nickel. For more information visit \u003c\/span\u003e\u003ca href=\"http:\/\/www.P65Warnings.ca.gov\"\u003ewww.P65Warnings.ca.gov\u003c\/a\u003e\u003c\/p\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e","brand":"Wiggins","offers":[{"title":"Default Title","offer_id":49321724903657,"sku":"JNXPH","price":2718.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1425\/8938\/files\/300x300-Wiggins-JNXPH-Automatic-Shutoff-Valve-for-Compact-Non-Pressurized-Fast-Fuel-Fill-System.png?v=1791839767","url":"https:\/\/store.industriallubricant.com\/products\/wiggins-defvalvehr-diesel-exhaust-fluid-filling-systems-automatic-shutoff-valve-copy","provider":"Industrial Lubricant","version":"1.0","type":"link"}